How To Replace Damaged Subflooring Under Toilet – Home Repairs



http://www.homebuildingandrepairs.com/repairs/framing/floors/index.html Click on this link for more videos about floor framing repairs, new home construction and building design. This video will provide you with a few ideas about how you can repair would subflooring damage caused from a leaking toilet. The main point in this video will be to provide you with a method for installing the new subflooring underneath the toilet flange instead of around it.

source

49 thoughts on “How To Replace Damaged Subflooring Under Toilet – Home Repairs”

  1. My wife and I bought a home for very cheap on an estate sale in Washington. Subfloor in the master bedroom we discovered had mold, after pulling the plywood above the subfloor we discovered there was atrocious rot. When tapping the rot near the flange my tool almost fell through and the subfloor crashed through to the crawl space. While referencing your video I added joists, support, blocking, and have almost finished replacing the subfloor. We are doing all the work on this ‘94 home ourselves and videos like this are life savers. You have saved me thousands of dollars and stress. God bless you and I hope you are doing well. From the Lee family.

  2. We appreciate the detailed walkthrough on repairing subflooring! Cutting out the damaged area seems crucial, especially around plumbing. I’ve learned that using blocks for support under the new plywood is a smart move, as it helps stabilize everything.

    I once tackled a similar project and found that measuring carefully around flanges made all the difference. It’s amazing how much easier the installation becomes with proper planning.

    Also, the tip about using brass screws is spot on—who knew they could help prevent movement? Thanks for sharing your insights; they definitely make tackling these repairs less daunting! Keep up the great work!

  3. Great video, but I don't understand why you would lay your blocking flat as opposed to upright. You can install upright blocking between the joists on either side of the flange, half of the width under the existing subfloor and half under the new subfloor. If there are two layers of subfloor totaling at least an inch thick I would think that would offer plenty of support. Laying the blocking flat won't offer the same amount of support, correct?

  4. Why not replace the flange which is probably damaged from the toilet rocking on the rotted floor, so that the subfloor repair can be a solid single piece with a hole (hole saw) so the flange can be installed the right way? Stronger and probably easier.

  5. For a circle, you can use a scrap piece of cardboard, trim nail and pencil. Put ur nail trough the cardboard and mark the radius of the circle with your pencil and put ur nail through your measured radius for your pencil lead to sit in. Attach one hole of cardboard to the center of your circle with the nail and have your pencil led through the other hole and mark your circle.

  6. Great video! One suggestion I have is that you take your replacement peice and trace it to the damaged floor for a perfect fit. it is difficult to cut a perfect square without a reference edge in the middle of the floor.

  7. Firstly, you’re in a league of your own. The CAD drawings, the explanation, all top notch, and always. But I’m curious as to your suggested orientation of the blocking beneath the subfloor itself. Laid horizontally, (instead of sistered to the joists and blocked perpendicularly), I’d imagine this would afford very little structural support underneath the toilet. Most people literally plop themselves down on toilets. I wouldn’t trust blocking that was laid flat underneath the plywood as shown in this video. It seems like a tremendous amount of strain placed on very few attachment points to the actual structural members below. Please correct me if I’m mistaken.

  8. Thanks, going to need less plywood than I thought. I agree about cutting around the flange, that's how the floor was cut for my old cast iron flange, and it made a temporary flange replacement impossible without some kind of backing. Thankfully they sell steel backing/brackets that fit around the flange and creates a support, which you can fasten to the subfloor wider around the flange, and then fasten the flange itself to the steel backing/bracket.

    My subfloor was so bad that I had to temporarily shim the toilet after replacing the flange, otherwise the toilet rocked. I used one of those plastic replacement flanges on a cast iron pipe, which worked okay, but I wouldn't use one again on a cast iron pipe due to height limitations, in this case the flange was too high in its lowest position. Replacement cast iron flanges wrap around the pipe, rather than fitting inside, so there is more freedom to raise the flange up and down. When I replace the subfloor I'm going to get rid of that plastic flange and put on a new cast iron replacement. Should have done that in the first place, but these are things you learn by doing, I guess.

    This is also probably a good time for anyone to replace the flange, especially if you have an old cast iron one, since you will be able to just place the subfloor over the flange after cutting a hole rather than cutting the board in half or more pieces.

  9. Great information, very helpful., thank you! I was about to cut the pipe and reinstall a flange elbow, but this may be more reasonable and appropriate. If my new subfloor is 1/4 inch thinner than the old sub floor, would you suggest I install those support boards 1/4" higher to compensate? Or install the supports and plywood pieces THEN floor leveler after to even it out?

  10. I have to replace my Damaged Subfloor under my toilet but I'm confused about the cut around the toilet drain pipe, should I cut my hole in the plywood around the DRAIN PIPE or the Flange? Any help would be appreciated………

  11. Not putting in blocks was one of the mistakes made when our subfloor broke under the toilet. Using OSB to replace the plywood was another big big mistake. It's not the same height as the old floor. And since the plywood wasn't cut to the joist, it is floating and is squishy in that spot.

  12. Thank you for making these videos!! I am about to try to repair my parents rotted subfloor under the toilet. Extremely paranoid and nervous about being able to do it. Been repeatedly watching this video.
    Can you quickly explain how the blocking is placed around the pipe? I understand the 2 blocks that connect to both joists. Its the wider pieces. Where do those ge screwed in? Are they also screwed into the joists and added blocks?

Leave a Comment

Your email address will not be published. Required fields are marked *

Shopping Cart